GE Healthcare · CTLightSpeedVCT260133156260101028109585210326010102350444260007402
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260133156 CAM A/B Move Timeout Timer expired - move did not complete in time See long description for full error Mon Sep 29 07:35:25 2008 Error: 260133156 Host: orp Process: orp_subsys File: ccb_drive_timers.cxx Line: 362 Mon Sep 29 07:35:23 2008 Host : Collimator Ermes # : 260133156 Exception Class : Abort Severity : Primary File : ccb_drive_timers.cxx Line# : 362 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 CAM A Move Timeout Timer expired - move did not complete in time Error: 260101028 The DCB has shutdown due to an error. A controller reset is required to continue. 1095852103 0 1 Wed Sep 22 11:21:43 2004 260101028 4 orp orp_subsys rcib_erlog.c 217 Wed Sep 22 11:21:41 2004 Host : On-Board Rotating Processor Ermes # : 260101028 Exception Class : Soft Severity : Pri/Soft File : rcib_erlog.c Line# : 217 Function : No System Function Reported Scan Type : None/Unknown Scan: 26/2/0 The DCB has shutdown due to an error. A controller reset is required to continue. 1095852103 0 1 Wed Sep 22 11:21:43 2004 260101028 4 orp orp_subsys rcib_erlog.c 217 Wed Sep 22 11:21:41 2004 Host : On-Board Rotating Processor Ermes # : 260101028 Exception Class : Soft
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required