GE Healthcare · CTLightSpeed
LightSpeed 4.X - GRE
Symptom
Subtle Band / Ring Artifact in head images. See Long Description for details. Subtle Band / Ring Artifact in head images
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2120109 COPPER FILTER FOR GEMINI X-RAY TUBE WITH HELIOS COLLIMATOR See Long Description for details Part #: 2120109 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: COPPER FILTER FOR GEMINI X-RAY TUBE WITH HELIOS COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - COPPER FILTER USED ON XRAY TUBES MS6075/CGM/07-17-00 REQUESTED OF ERWIN SAULMA Made SPARE N PER ECR 2003044, MUST ORDER NEXT HIGHER ASM, TUBE. MS13452 Mounting Plate for D3176T & D3186T has copper filter located on outside. - Copper filter now accessible for IQ troubleshooting (held in place by 8 small Philips-head screws) - Copper filter is a FRU (p/n 2120109) - Reminder, DO NOT remove bolts holding mounting plate to tube
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required