GE Healthcare · CTLightSpeedVCT200002357210000431210000428210000430210000447
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Applications software fails to boot up completely and automatically shuts itself back down. Applications software fails to boot up completely and automatically shuts itself back down
Error message
Error: 200002357 A HOST SHUTDOWN was initiatied by the unexpected termination of dms since other processes depend on it to come up. See long description for a sample error. Tue Mar 18 08:58:45 2008 Error: 200002357 Host: jghls64 Process: cupMonitor File: ssProcStop.c Line: 954 A HOST SHUTDOWN was initiatied by the unexpected termination of dms since other processes depend on it to come up. Error: 210000431 Failed to intialize client session for save context with error 2 See long description for sample error. Tue Mar 18 08:58:45 2008 Error: 210000431 Host: jghls64 Process: dms File: SaveContext.cxx Line: 41 Failed to intialize clien session for save context with error 2 Error: 210000428 Unable to establish connection for repository iosterra|terradb session See long description for full error Tue Jan 29 06:51:29 2008 Error: 210000428 Host: gevct2 Process: dms File: Initialize.cxx Line: 396 Unable to establish connection for repository iosterra|terradb session Error: 210000430 Failed to initialize SaveContext with status -1 See long description for sample error. Tue Mar 18 08:58:45 2008 Error: 210000430 Host: jghls64 Process: dms File: Initialize.cxx Line: 410 Failed to initialize
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required