GE Healthcare · CTLightSpeedVCT230011073403010440230019002
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE
Symptom
"Scan hardware Stopped Scan" with scan data errors. "Scan hardware Stopped Scan" with scan data errors
Error message
Error: 230011073 STUB -SCANFILE_HEADER_callback See LD for full error Mon Jun 27 09:56:31 2005 Error: 230011073 Host: ct01 Process: headermgr File: sdio_xfs_api.c Line: 4074 STUB - SCANFILE_HEADER_callback Fri Sep 29 13:35:26 2006 Error: 230011073 Host: ct01 Process: badchanmgr File: sdio_xfs_api.c Line: 4101 STUB - SCANFILE_HEADER_callback Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 2 --- No such file or directory then repeats ... Fri Sep 29 13:35:26 2006 Error: 230011073 Host: ct01 Process: scanmgr File: sdio_xfs_api.c Line: 4101 Function: Data Acquisition : SBC Processing Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 11 --- Resource temporarily unavailable then repeats... Fri Sep 29 13:35:46 2006 Error: 230011073 Host: ct01 Process: scanfile_xfer File: sdio_xfs_api.c Line: 4101 Function: Image Generation : SBC Processing Scan Type: Not scanning Scan: 41/3/1 Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 13 --- Permi
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required