Pular para o conteúdo principal
GE Healthcare · CT260118219

CT/e, CT Prospeed AI/FI Irix or Linux

Symptom

Scan Aborts with JEDI XG Error. Scout Scan Aborts with JEDI XG Error

Error message

Error: 260118219 (60-0323) ILP and ILR current not OK from - CT TIC See LD for error explanation Code 60 Exposure Errors Error code: 60-0323H Message/explanation: ILP and ILR current not OK No inverter current measures at the beginning of the exposure Potential cause: DCBUS lost Inverter PPC kV control board Recommended action/ Troubleshooting guide: Check main DCBUS voltage on inverter Take some exposures. If error persists, run HV power diagnostics. Check connections of resonant elements in Inverter. Run Inverter gate command diagnostic. If test fails replace Inverter. Run Inverter in short circuit test. If test fails replace Inverter or PPC kV control board.

Applies to

Product
CT/e, CT Prospeed AI/FI Irix or Linux See long description for sale information Product Name: CT/e Single CT Scanner: Irix Platform A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) 3.01 / 3.02 / 3.03 Linux CTe Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found in the attachment Always use the most appropriate documentation for your system.
Component
5126989 Jedi Xi Series Inverter Mid Power assembly use ONLY with glass tube (replaces 2215814) See long description for details Part #: 5126989 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: INVERTER MID POWER ASSY_FRU FRU: Yes Status: Orderable Comments: Use only with for GLASS X-ray tubes 2250110 -- 125A Fuse -- Used in YMS HiSpeed PDU see long description Part #: 2250110 Part Type: GP CONSUMABLES Part Weight: 0.08 KGM Repairable: No Returnable: No Hazardous Material: N Description: MISC ELECTRONIC COMPONENT TEMPORARY FRU: Yes Status: Orderable Comments: FLS - FUSE , F10, 125A U/O YMS CT HISPEED ZXI MS08992 9/30/99
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues