Operator tries to set up a scan and system indicates there are not enough scan files available and to release scan files
Symptom
Operator tries to set up a scan and system indicates there are not enough scan files available and to release scan files Operator tries to set up a scan and system indicates there are not enough scan files available and to release scan files.
Error message
Error: 230008060 Unable to allocate requested scans, insufficient scan structures See long description for details Error: 230008060 Unable to allocate requested scans, insufficient scan structures. Wed Aug 5 19:21:19 2009 Error: 230008060 Host: ge ls64 ct Process: autotest File: sfm api.c Line: 985 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 0/0/0 Unable to allocate requested scans, insufficient scan structures. First Scan: CT33/1306/2/1 Scan structures required: 1 Scan structures available: 0 Error: 245215 Scan setup failed on Step:3 (Allocate Scan File). See long description for full error Fri Sep 19 09:15:37 2008 Error: 245215 Host: ct10 Process: scanmgr File: scanmgr lib.cxx Line: 1167 Function: System Control : Scan Control S can Type: Scout Scan: 0/0/0 Scan Seq Id: 7000 Scan setup failed on Step:3 (Allocate Scan File). Error: 245047 Unable to allocate scan files See the long description for the full error code Thu May 12 17:43:37 2005 Error: 245047 Host: rrmcct16 Process: scanmgr File: scan_sequence.cxx Line: 1461 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 601000 Unable to allocate scan files
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed Select, Delight Select or MERI Select Elite-16, Edge-8, Excel-4 HP_S_G16_G_HLT HP_S_G8_G_HLT HP_S_G4_G_HLT BrightSpeed Select or Delight Select (Hivalue Lite) 4/8/16 Slice Scanner BrightSpeed Delight Select Systems started to ship in first Quarter or 2009 with AIO (All in One) Console. AIO console uses HP8400 and NO DARC or IG's. Recon time is 6 FPS. If customer orders Fluoro option system requires one IG. The 16 FPS Upgrade in Not Available for Select systems. BrightSpeed Meri Select Systems ( Pancake Das ) started to ship in 3rd quarter of 2010, 4/8/16 Slice Scanner HiValue 16 Lite −−> BrightSpeed Elite Select HiValue 8 Lite−−> BrightSpeed Edge Select HiValue 4 Lite−−> BrightSpeed Excel Select BrightSpeed Select Scope: - 3.5MHu Solarix tube - JEDI 60 dc Lite - Modified NP Table Key Features: - 16x0.625mm(16x1.25) for Lite 16 - 8x1.25/8x2.5mm for Lite 4/8 - Rotation Speed: 0.8 s - Gantry: 2040mm width, 70cm Bore - Table: 1337@ISO-140mm scannable range - Recon: 3fps (w/o IG @ 2G Memory(4/8), 4G Memory(16)), optional: 6fps(w/ 1IG ) - Power: 42KW JEDI power See the attached Service Intro Planner for details Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT