Scanner Hardware Stopped Scan with open filament

Symptom

Scanner Hardware Stopped Scan with open filament error in log. Scanner Hardware Stopped Scan with open filament error

Error message

Error: 260105063 The Filament FPGA Status error. Jedi (50-0219) See long description Mon Jan 4 20:20:53 2010 Error: 260105063Host:orp orp_subsysgen_exec.cxx 2792Mon Jan 4 20:20:46 2010Host : Jedi Ermes # : 260105063Exception Class : Abort Severity : PrimaryFile : gen_exec.cxx Line# : 2792Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0 (50-0219) The Filament FPGA Status error. Z6,Z7= 11h,11h

Error: 245213 Scan was Paused/Aborted by Firmware (or the host) This is mostly a generic error See LD for error examples Error 245213 is a generic error caused by scan file manager Wed Apr 27 01:01:26 2005 Error: 245213 Host: ls16er Process: scanmgr File: scanmgr_events.cxx Line: 1617 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 107000 Scan was Paused/Aborted by Firmware You may also see another form of this error. Thu May 12 17:43:37 2005 Error: 245213 Host: rrmcct16 Process: scanmgr File: scanmgr_lib.cxx Line: 968 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 601000 Scan setup failed on Step:3 (Allocate Scan File). Status:245047 Another form of this error. Fri Jan 12 10:17:15 2007 Error: 245213 

Applies to

Models
Discovery
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
D3701T : PERSEUS TUBE UNIT - Used on CT750 HD See Long Description for details. Part #: D3701T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERSEUS TUBE UNIT (GREEN) FRU: Yes Status: Orderable Comments: Per HDVCT RSPL, 212008898, 8/19/08. ** FE ASSIST ** Important to have adequate HV oil in the HV Wells. Making sure some oil does overflow when inserting Candle stick. (212001261 4/6/09)
Area
CT