GE Healthcare · CTLightSpeedVCTBrightSpeed244644244645244643
LightSpeed 4.X - GRE
Symptom
Pop-up appears upon boot-up: An unrecognized X-Ray tube has been installed on the system.
Error message
Error: 244644 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report. See LD for more details Sat Jun 17 10:21:57 2006 Error: 244644 Host: jfkct2 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 329 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report. Error: 244645 The system has been configured to recognize a GE Medical Systems Performix? tube for a 30-day period See long description for full error Tue Apr 10 21:07:28 2007 Error: 244645 Host: ct02 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 255 Tube verification reminder: The system has been configured to recognize a GE Medical Systems Performix® tube for a 30-day period. Error: 244643 Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. See Long Description for complete error Thu Dec 21 15:35:37 2006 Error: 244643 Host: nsuhct2 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 326 Tube identity advisory: An unre
Applies to
- Models
- LightSpeed, VCT, BrightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required