GE Healthcare · CT186218
CT/e, CT Prospeed AI/FI Irix or Linux
Symptom
Unable to scan with XG errors
Error message
Error: 186218 XG (80 - 1405H) Hardware error : HV Tank temperature too low See Long Description for Details Sun Feb 24 03:22:03 2008 Error: 186218 Host: IMCT Process: tgp_out File: tgp_in_input.c Line: 335 XG Error phase is 2 code is 80. detail error code : 80 - 1405H Hardware error : HV Tank temperature too low
Applies to
- Product
- CT/e, CT Prospeed AI/FI Irix or Linux See long description for sale information Product Name: CT/e Single CT Scanner: Irix Platform A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) 3.01 / 3.02 / 3.03 Linux CTe Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found in the attachment Always use the most appropriate documentation for your system.
- Component
- 5126995-2 PROGRAMMED KV CONTROL BOARD P5.2 used on CTe,YMS (2230555-6,2230555-7) See Long Description Part #: 5126995-2 PROGRAMMED KV CONTROL BOARD P5.47_FRU Displaying Change-Up Data: Part "2230555-7" changed to "5126995-2" Part #: 5126995-2 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: PROGRAMMED KV CONTROL BOARD P5.47_FRU FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 5126995-2 Harvested: Not Available Exchange: Not Available ------------------------------------------------------------------- From part # 2230555-6 ** FE ASSIST ** if no stock of the 2230555-6 use 5126995-2 (212001261 7/7/09) FLS - KV BD PER ASIA USE 2230555-7 DEPENDING OF SYSTEM IN PLACE , YOU HAVE NOW TO ORDER FOR ALL PRODUCT USING JEDI RAD (GERAD/SILHOUETTE/PROTEUSPLS ORDER # 2265276-3FOR CT USING GENERATOR # 2238776 PLS ORDER # 2265276-3FOR CT USING GENERATOR # 2227720 PLS ORDER # 2230555-7FOR CT HIGHSPEED LX/I, FX/I, DX/I, CT/E PLS ORDER # 2230555-7..MS27898 ------------------------------------------------------------------------------------ 2230555-7 PROGRAMMED KV CONTROL BOARD P5.2 Part #: 2230555-7 Part Type: GP CONSUMABLES Part Weight: 1.36 KGM Repairable: No Returnable: No Hazardous Material: N Description: PROGRAMMED KV CONTROL BOARD P5.2 FRU: Yes Status: Orderable Parts Offered as: Current: 2230555-7
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required