Symptom

"Scan hardware Stopped Scan" with collimator errors. "Scan hardware Stopped Scan" with collimator errors

Error message

Error: 260003121 The Aperture failed to move to the requested position. See LD for complete error Mon Dec 6 12:55:55 2004 Error: 260003121 Host: HSC Process: CCB Firmware File: aperture_move.c Line: 225 Running diagnostic: Collimator Functional Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 12:55:56:165 Log Series: 63 The Aperture failed to move to the requested position.

Error: 260003171 CAM A Failed to Move To the Correct Position For Beam Tracking. See long description for complete error Error: 260003171 Host: HSC Process: CCB Firmware File: aperture_z_axis.c Line: 755 Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 8675/2/4 Type: Axial Exception Level: Sec/Soft Time: 15:51:42:475 Log Series: 53 CAM A Failed to Move To the Correct Position For Beam Tracking. Actual Position : 1816um 525cnt Expected Position: 1714um 539cnt Move Tolerance : 100um

Error: 260003118 CAM A drive tracking detected the current motor position is out of the tolerance band for a successfull move See Long Description for complete error. Error: 260003118 CAM A drive tracking detected the current motor position is 

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT