GE Healthcare · CTLightSpeed244638244644244637244643

LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry.

Symptom

System could not find the tube type- auto-detect device message posted on monitor. System could not find the tube type- auto-detect device message posted on monitor

Error message

Error: 244638 Scanning with the improper tube configuration can cause damage to the tube. Continue at your own risk Status from the generator: -4 See LD for complete error Mon Nov 15 13:41:38 2004 Error: 244638 Host: ct01 Process: fwmgr File: fwmgr_fw_if.cxx Line: 443 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Scanning with the improper tube configuration can cause damage to the tube. Continue at your own risk Status from the generator: -3 Note: Generator Status -3 means we cannot communicate with SmartID at all Generator Status -4 means we communicated but received a bad response

Error: 244644 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report. See LD for more details Sat Jun 17 10:21:57 2006 Error: 244644 Host: jfkct2 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 329 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report.

Error: 244637 System could not f

Applies to

Models
LightSpeed
Product
LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
08BW17.7 For LightSpeed RT16 & RT16 Xtra See LD for details 08BW17.7 For LightSpeed RT16 & RT16 Xtra sw_hw_string: 08BW17.7.WB_H_G16_G_GTM Released with FMI 22918 Purpose This FMI delivers software release 08BW17.7 to LightSpeed RT16 and LightSpeed Xtra. This software improves the tube warm-up procedure, and delivers safety and quality fixes to improve system reliability. See Product Quality Fixes and Product Safety Fixes section for further details. See Appendix C (In attachment) for improved tube warm-up steps. Product Quality and Safety fixes are the fixes that were included in Service Pack 2.0 for 07MW11.0, 07MW18.4, and 07BW08.4. 5315090 - Class C (Tab# 182) 5315091 - Class M (Tab# 182)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.