GE Healthcare · CT
Sytec 1600i/1800i SYj Eu
Symptom
Unable to scan with XG errors
Error message
ER-113 XG Error - contains information on all XG ER113 errors See long description for detailed error codes and sub codes. ER–113 XG Error LED STATUS = uvwxyz, %%%KV, %%%MA, HV TIME=%%%%%msec NV TIME: Time between HV ON and XG FAIL LED STATUS=uvwxyz: This hexadecimal code shows the LED status (D23 ~ D39) on the Power Cont Assy into the X0Ray Generator as shown: u: 0 ~ 3 0 0 D23 D24 D23: Over voltage P4 D24: Over voltage N4 v: 0 ~ F D25 D26 D27 D26 D25: Over Voltage P1 D26: Over Voltage N1 D27: Down Voltage P4 D28: Down Voltage N4 w: 0 ~ 3 0 0 D29 D30 D29: Over Load P D30: Over Load N x: 0 ~ F D31 D32 D33 D34 D31: Over Heat D32: Rotor Over Current D33: Filament Over Current D34: Power Fail y: 0 z: 1 ~ 7 D35 D36 D37 D38 1: HV ON Over time (more than 14.67sec below 100mA) 2: HV ON Over time (more than 5.64sec above 100mA) 3: FIL3 SW does not match soft SW. 4: Can not select 80 or 140 kV for soft SW. 5: RAM over error 6: RAM set error 7: RAM clear error ER-117 XG Fail - contains information on all XG ER117 errors See Long Description ER-117 XG Fail ER–117 ER – 117 : XG Error 00000XYY Error Code X = _ 0: Test Mode 1: Stand–by 2: Preparation Acting 3: Generator Ready 5: Exposure 7: Tran
Applies to
- Product
- Sytec 1600i/1800i SYj Eu Sytec 1600i/1800i SYj Eu Sytec 1600i/1800i SYj Eu Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3512T X ray tube used on Sytec 1800i / 1600i See lond description Part #: D3512T Part Type: GP TUBES Part Weight: 0.91 KGM Repairable: No Returnable: Yes Hazardous Material: N Description: CT PLUS TUBE UNIT RELOAD FRU: Yes Status: Orderable Parts Offered as: Current: D3512T Harvested: Not Available Exchange: Not Available Comments: FLS - MAXIRAY EQUIVALENT IS D3519T *WARNING: CT PLUS IS A NEW TUBE DEDICATED FOR SYTEC 1800I, SYTEC 1600I AND CT EMYU SYSTEMS ONLY. PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI 28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS *NOT* COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FLS - CT PLUS TUBE. FOR SYTEC 1800I, SYTEC 1600I AND CT EMYUSYSTEMS ONLY. "WARNING: PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS NOT COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FOR THESE SYSTEMS YOU SHOULD PLACE ORDER FOR CT MAX TUBE: D3502T. PLEASE CALL ONLINE CTR IF YOU NEED FURTHERCLARIFICATION." CPD TEAM: NO SYSTEMS IN USA IN 1998. IF FOR DOMESTIC ORDER, FE IS PROBABLY ORDERING INCORRECTLY. (D HAWVER 9/24/98) SOURCE = ASIA (GE-BEL IN INDIA) TUBE DEDICATED FOR SYTEC 1800I, SYTEC 1600I AND CT EMYU SYSTEMS ONLY. PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI 28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS *NOT* COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FOR THESE SYSTEMS YOU SHOULD PLACE ORDER FOR CTMAX TUBE: D3502T* PLACE ORDER FOR CTMAX TUBE: D3502T*
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required