Symptom

A pink Attention box pops up during Fast Cal saying there is a problem with the DAS/Detector. Scanning will NOT be disabled. Image Quality will be compromised, call GE SERVICE. See long description for pop up message picture. A pink Attention box pops up during Fast Cal saying there is a problem with the DAS/Detector. Scanning will NOT be disabled. Image Quality will be compromised, call GE SERVICE. After clicking OK Fast Cal completes. ATTENTION: The system detected a problem with the DAS/Detector sub-system. Image Quality will be compromised. Scanning will NOT be disabled, but it is critical that the user call GE SERVICE to rectify the problem. Press 'OK" to proceed at the risk of Image Artifacts

Error message

Error: 260132753 Digital Interface Board(s) Encountered An Error During ASIC Linearization See Long Description for complete error Mon Oct 31 07:18:07 2005 Error: 260132753 Host: orp Process: orp_subsys File: Ifb.cxx Line: 504 Mon Oct 31 07:18:06 2005 Host : Das Ermes # : 260132753 Exception Class : Secondary Severity : Sec/Soft File : Ifb.cxx Line# : 504 Function : No System Function Reported Scan Type : Axial Scan: 50043/5/7 Digital Interface Board(s) Encountered An Error During ASIC Linearization DIFB : 4 Chan : 1430 Stage : 2 This error format was introduced in 07MW18.4_SP2-26.V40_H_H64_G_GTL with SP2 release . We no-longer need the decoder since this error report the FRDM as A/D 41 . Wed Jan 7 08:40:45 2009 Error: 260132753 Host: orp Process: orp_subsys File: Ifb.cxx Line: 890 Wed Jan 7 08:40:44 2009 Host : Das Ermes # : 260132753 Exception Class : Abort Severity : Secondary File : Ifb.cxx Line# : 890 Function : No System Function Reported Scan Type : Axial Scan: 50018/1/3 Digital Interface Board(s) Encountered An Error During ASIC Linearization DIFB : 21 A/D Board: 41 Chan : 3369 Stage : 3 Coeff : 22 Other Examples: From software releases prior to 2009, the following error fo

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5196402 FRDM for Outer Modules used on VCT HDAS-64 See Long Description for details 5196402 FRDM Module for OUTER SLOTS used on VCT HDAS-64 Part #: 5196402 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: FIELD REPLACEABLE MODULE KIT - OUTER SLOTS FOR HALO CONVERTER CARD FRU: Yes Status: Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.