GE Healthcare · CTLightSpeedVCT26011825424463724462160333

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

System could not find the tube type- auto-detect device message posted on monitor. System could not find the tube type- auto-detect device message posted on monitor

Warning pop-up appears on screen with Tube identity advisory. See Long Description for complete text of message. ! Attention An unrecognized X-Ray tube has been installed on the system. - GE Medical Systems cannot assure that the system performance will conform to specifications. - Advisory messages will be posted to the operator about an unrecognized tube during tube warm-up, during Fast Calibration, and in the dose report.

Error message

Error: 260118254 (80-1414)Internal LD CAN bus Txo See Long Description for complete error Tue Oct 27 13:57:02 2009 260118254 2 orp orp_subsys gen_exec.c 2446 Tue Oct 27 13:56:44 2009 Host : Jedi Ermes # : 260118254 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2446 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 (80-1414)Internal LD CAN bus Txo._ Z6,Z7= 0h,0h

Error: 244637 System could not find the tube type auto-detect device. Scanning is not disabled. However, please verify the tube type. See LD for complete error Mon Nov 15 13:41:38 2004 Error: 244637 Host: ct01 Process: fwmgr File: fwmgr_fw_if.cxx Line: 441 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 System could not find the tube type auto-detect device. Scanning is not disabled. However, please verify the tube type.

Error: 244621 Timed out while attempting to receive a message. See long description for full error. Wed Aug 22 07:19:18 2007 Error: 244621 Host: mcc1 Process: fwmgr File: fwmgr fw if.cxx Line: 99 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Did not receive reply from a reque

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required