Pular para o conteúdo principal
GE Healthcare · CTHiSpeed18416295121603831184170183403

HiSpeed CTi 6.X with Octane and HSA Gantry

Symptom

"Scan hardware Stopped Scan" with collimator errors. "Scan hardware Stopped Scan" with collimator errors

Error message

Error: 184162 Axial: Ok Collimator: Timeout Table: Ok Generator: Ok SARQ: Ok See LD for full error Error: 184162 Axial: Ok Collimator: Timeout Table: Ok Generator: Ok SARQ: Ok Sat Dec 16 04:33:57 1995 Error: 184162 Suite: GECT Host: STC Proc: Scan Control File: scReRefMgr.c 1.22 Method: No Method Line: 222 951216 0446 03831 Function: No System Function Reported Scan: 3102/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 04:33:56:985 Log Series: 172 Error detected in end-of-series operations. HW/SW Error: Possible hardware (reference) or software error. Status 0x4d: Axial: Ok Collimator: Timeout Table: Ok Generator: Ok SARQ: Ok

Error: 184170 Collimator was not ready See long description for details Sun Nov 4 15:05:10 2007 Error: 184170 Collimator was not ready. Collimator firmware object command timed out.

Error: 183403 Filter did not reach final position in time Sat Dec 16 04:39:20 1995 Error: 183403 Suite: GECT Host: OBC Proc: Collimator File: move filter.c 1.13 6/24/9 Method: No Method Line: 98 Function: XRAY GENERATION : Xray Collimation and Filtration 951216 0445 03831 Scan: 3102/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 04:39:19:315 Log Serie

Applies to

Models
HiSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-296300G4 and 46-296300G5 EMC COLLIMATOR -used on CTi and compatible to HSA See LD for more info 46-296300G4 and 46-296300G5 EMC COLLIMATOR -used on CTi and compatible to HSA picture 46-296300G4 EMC COLLIMATOR Part #: 46-296300G4 Part Type: GP REPAIRABLES Part Weight: 19.54 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: 860-950117 EMC COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - FE: READ SERVICE NOTE T-1379 5/96 GVR T3202GR MPS INFO: B7999KK CONTAINS G4 COLLIMATOR PLUS S/W. MFG PLANIS TO DEINSTALL THE G3, HAVE FE RETURN, UPGRADE, AND USE INADDITIONAL KITS PER R. KOPP. 10/95 FLS - FE ASSIST MS6588 5/2000 46-296300G4 = GRAPHITE FILTER COLLIMATOR. IF NO STOCK IS AVAILABLE ORDER 46-296300G5. THE G5 COLLIMATOR IS COMPATIBLE ON CTI HSARP AND HSAZ SERIES SYSTEMS. DO YOU STILL WANT TO ORDER THIS PART??? Part #: 46-296300G5 Part Type: GP REPAIRABLES Part Weight: 19.09 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: EMC COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - COST REDUCED EMC COLLIMATOR USED ON FAST RHAPSODE 7/2/97 GWENN 08992 T3202KM 11/19/02 -BUILD OUTSOURCED FRMCT MFG TO ERDA PER GINA DUNDUNM KRAETSCH. MS12464 FLS - FE ASSIST MS6588 5/2000 T3202KM = G5 COLLIMATOR COST REDUCED EMC COLLIMATOR USED ONHSARP, HSA AND CTI SYSTEMS. THE G5 (T3202KM) WILL NOT WORKON HELIOS/LIGHTSPEED SCANNERS. DO YOU STILL WANT TO ORDER THIS PART???
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues