GE Healthcare · CTLightSpeed26011824150000

LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry.

Symptom

Cannot perform tube warmup. Cannot perform tube warmup

Error message

Error: 260118241 (80-0180) Rotation board communications problem. See LD for full error Wed Mar 2 16:58:01 2005 Error: 260118241 Host: orp Process: orp_subsys File: gen_exec.c Line: 2148 Wed Mar 2 16:57:59 2005 Host : Jedi Ermes # : 260118241 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2148 Function : No System Function Reported Scan Type : Axial Scan: 50000/1/3 (80-0180)Rotation board communication problem. PPC board communication Watch Dog with Rotation board popped up because it did not get reply from Rotation board. Z6,Z7= 0h,0h Error: 260118241 (80-0180) Rotation board communication problem Code 80 Hardware Errors Error code: 80-0180H Message/explanation: Rotation board communication problem. PPC kV control board communication Watch Dog with Rotation board popped up because it did not get reply from Rotation board. Potential cause: Rotation board Control bus cable PPC kV control board Recommended action/ Troubleshooting guide: Verify the CAN cable between PPC kV control and auxiliary module is correctly connected to the Rotation board Check that rotation firmware is running (DS5 on rotation board blinking). If firmware OK, replace PPC kV control board.

Applies to

Models
LightSpeed
Product
LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2324118-3 VCT-JH4 Auxiliary Equipped. Aux Box See Long Description for details Part#:2324118-3 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT-JH4 AUXILIARY EQUIPED FRU: Yes Status: Orderable Comments: Set as Critical Part for Product CT_VCT, ms04278, 05Oct28 Added per VCT RSPL, ms13452 041205 Picture below 2281950-3 or 2281950-4 : JH4 INVERTER WITH SHIELDS used on LS 5.X (80/100), LS 7.X See Long Description for Details 2281950-3 Can also use 2281950-4 JH4 INVERTER WITH SHIELDS used on LS 5.X (80/100), LS 7.X Part #: 2281950- 3 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: JH4 INVERTER WITH SHIELDS FRU: Yes Status: Orderable Comments: added per ecr 2005924, as replacement for 2281950 and 2281950-2. ms13452 040923 Set as Critical Part for Product CT_VCT, ms04278, 05Oct14 - If you receive an inverter as FRU (P/n 2281950, 2281950-2, 2281950-3) that must be installed to replace a defective inverter on site, check first Part number of PPC kV control board in this FRU: - if it is labelled 2351200-11 rev 001 this board needs to be replaced with the kV control board that is installed in the defective inverter: PPC board replacement, please refer to PPC FRU replacement procedure in service manual. - if it is not labelled 2351200-11 rev 001, the board installed on FRU is good: no modification is needed. Shawn Fox 3-24-05 Part #: 2281950 -4 Part Type: GP CONSUMABLES Part Weight: 0.00 LBRPart #: 2281950-4 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: JH4 INVERTER WITH SHIELDS FRU: Yes Status: Orderable Comments: Added per ECR 2018129, THIS PART IS BACKWARD COMPATIBLE REPLACEMENT FOR 2281950-3, -2, & NO DASH. MS13452 050919 Repairable: No Returnable: No Hazardous Material: N Description: JH4 INVERTER WITH SHIELDS FRU: Yes Status: Orderable Comments: Added per ECR 2018129, THIS PART IS BACKWARD COMPATIBLE REPLACEMENT FOR 2281950-3, -2, & NO DASH. MS13452 050919
Area
CT