GE Healthcare · CTLightSpeed260003100
LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry.
Symptom
"Scan hardware Stopped Scan" with collimator errors. "Scan hardware Stopped Scan" with collimator errors
Error message
Error: 260003100 CAM B Motion With Out Command Exceeded The Error Tolerance. Desired Position : 251um 797cnt Current Position : 415um 763cnt Error Tolerance: 44um Mon Dec 6 13:01:26 2004 Error: 260003100 Host: HSC Process: CCB Firmware File: ccb_drive_timers.c Line: 277 Running diagnostic: Collimator Functional Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 0/0/0 Type: None/Unknown Exception Level: Sec/Soft Time: 13:01:27:185 Log Series: 42 CAM B Motion With Out Command Exceeded The Error Tolerance. Desired Position : 251um 797cnt Current Position : 415um 763cnt Error Tolerance: 44um
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5140001-4 helios 4 collimator with notched filler bar and rating plate used on 5.X scanners. See Long Description for Details. Part #: 5140001-4 Part Type: GP REPAIRABLES Part Weight: 2.20 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: helios 4 collimator with notched filler bar and rating plate FRU: Yes Status: Orderable Comments: Added by ECR 2013518 as ms13452 050428 **FE Assist** Used on H-power - main difference is the mount holes are larger to accommodate for larger bolts to hold the added weight of the Hercules Tube. 5140001-4 is also used on HP-60 s . 514001-4 is not backwards compatible.(12/5/06 212001261) *** 2ND OPINION NOTES *** Replacing for artifacts? Look into collimator with bright light. Any particulate? Look at plastic over copper filter, any distortion or yellowing? Bow tie filter ok? There are several lower level FRUs. Ensure that one of the lower level FRUs could not fix the problem.
- Area
- CT