GE Healthcare · CTHiSpeed200105007200501546200107004
System will not scan after changing time back one hour.
Symptom
System will not scan after changing time back one hour. Time was one hour fast and customer asked for it to be changed. System will not scan after changing time back one hour Time was one hour fast and customer asked for it to be changed.
Error message
Error: 200105007 Scanner software failed to process message with status -1 while Sending Scan Request See Long Description for complete error Thu May 28 17:15:23 2009 Error: 200105007 Host: PRESTCT Process: scanRx File: SubSystemIf.c Line: 654 Function: Data Acquisition : OC Processing Scanner software failed to process message with status -1 while Sending Scan Request Error: 200501546 Scanner software returned status -1 See Long Description for complete error Thu May 28 17:15:23 2009 Error: 200501546 Host: PRESTCT Process: scanRx File: uifIpcMgrScanRx.c Line: 4512 Function: Data Acquisition : OC Processing Scanner software returned status -1 Error: 200107004 Cannot send scan request, status -1 See Long Description for complete error Thu May 28 17:15:17 2009 Error: 200107004 Host: PRESTCT Process: scanRx File: srx_sma_manage_scan.c Line: 910 Function: Data Acquisition : OC Processing Cannot send scan request, status -1.
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Software
- 6.03 for HiSpeed series and CT/e, CT ProSpeed AI/FI series, DXi,FXi, LXi, ZXi 6.03 for HiSpeed series and CT/e, CT ProSpeed AI/FI series, DXi,FXi, LXi, ZXi 6.03 for HiSpeed series and CT/e, CT ProSpeed AI/FI series, DXi,FXi, LXi, ZXi Software Patch 6.02/6.03 Part Number 2323363
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required