Application software failed to boot with insufficent disk space message.
Symptom
Application software failed to boot with insufficent disk space message. Application software failed to boot with out of disk space message. See the long description for error codes from viewlog and SYSLOG Application software failed to boot with out of disk space message Thu Jun 23 07:02:15 2005 Error: 9071 Host: gtct3 Process: dbrserver File: proc.c Line: 376 get mail failed in process_mail() Thu Jun 23 07:02:15 2005 Error: 9056 Host: gtct3 Process: dbrserver File: server.c Line: 52 connection to Netserver failed, exiting... SYSLOG in /usr/adm: Jun 23 07:15:01 2C:gtct3 sendmail[2125]: NOQUEUE: SYSERR(root): queuename: Ca nnot create "qfHAA02125" in "/var/spool/mqueue" (euid=0): No space left on device Jun 23 08:28:45 3E:gtct3 ctuser: checkdisk: Disk partition /dev/usr is full (on gtct3).
Error message
Disk Space is Low message appears when rebooting saying , Call GE Service. See Long Description for details While scanning or booting up to applications, a Pop Up GUI appears saying: 1. Software Problem Detected on System. 2. Disk Space is Low. 3. See Error Log for which partition is causing the problem. 4. Complete current processes and shutdown system. 5. Call GE Service.
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- 2251435 P9231VF O2 SKL computer used on YMS Hispeed Irix console See Long Description Part #: 2251435 Part Type: GP REPAIRABLES Part Weight: -699993.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: P9231VF O2 SKL FRU: Yes Status: Orderable Comments: ** FW Assist**(4/27/05 212001261) May need to press the reset switch on the front of the O2 to start the computer the first time. Plus confirm the Flash Prom is set to 4.14 via hinv. Refer to Service note 124 for details
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.