GE Healthcare · CTLightSpeed2452835000324505036505200001821
LightSpeed 5.X (80/100kW)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 245283 Timeout (6000 ms) waiting on scan disk rezero response from dataacq See long description for full error Mon Nov 26 07:29:05 2007 Error: 245283 Host: svmcct16 Process: scanmgr File: scanmgr events.cxx Line: 1151 Function: System Control : Scan Control Scan Type: Not scanning Scan: 50003/2/0 Scan Seq Id: 0 Timeout (6000 ms) waiting on scan disk rezero response from dataacq. Error: 245050 Error verifying that Data Acquisition is ready for scanning Open Long Description to see error examples Error: 245050 Error verifying the Data Acquisition is ready for scanning. More than one error text exists for this error below: Fri Jul 1 16:51:14 2005 Error: 245050 Host: ct02 Process: scanmgr File: start_scanning.cxx Line: 231 Function: System Control : Scan Control Scan Type: Not scanning Scan: 483/1/0 Scan Seq Id: 1 Error -1 verifying that Data Acquisition is ready for scanning Wed Mar 3 16:56:16 2010 Error: 245050 Host: uhctlspro Process: scanmgr File: start_scanning.cxx Line: 250 Function: System Control : Scan Control Scan Type: Not scanning Scan: 36505/1/0 Scan Seq Id: 0 Error 200001821 verifying that Data Acquisition is ready for scanning
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 07MW11.10 for LS 1x2x3x4x5x, HS QX/i, & BSD 4/8/16 07MW11.10 for LS 1x2x3x4x5x, HS QX/i, & BSD 4/8/16 - Original FMI 25389 - Mandatory Safety FMI 25407 - Mandatory Safety - Service Pack 2.0 07MW11.10 for LS 1x2x3x4x5x, HS QX/i, & BSD 4/8/16 This software was updated by Mandatory Safety FMI 25407 ( Service Pack 2.0 for Software Versions 07MW18.4, 07MW11.10, and 07BW08.4), released 6/13/2008 (Initial Release) Always use the most appropriate documentation for your system. The following was taken from DIRECTION 5191771-100, REV 1 and is provided for your reference. Refer to DIRECTION 5191771-100, which can be found on CT LightSpeed CDROM/DVD, or if online at: FCT Service Engineering Tech Pubs Website , or Common Document Library . Software introduction - FIELD MODIFICATION INSTRUCTION / FMI 25389 Class C and Class M - 07MW11.10 Class C Software, p/n 5220446 - 07MW11.10 Class M Software, p/n 5220446-2 NOTE: 07MW11.10 Class C and M CDROMs were distributed to FE’s via a TAB #182 distribution in advance of this FMI. If you have not received them, contact your process leader to ensure you are on TAB #182’s distribution list. Order them through the GEMS Coakleytech website at http://coakleytech.med.ge.com/cgi-win/default.aspx Product Safety Fixes System shutdown due to X/IO error (multiple PSR's) Scan aborts, start scan fails to light, table or cradle not ready due to firmware start up issues on LightSpeed 5.X and BrightSpeed systems (multiple PSR's) Table moving down on it's own Advanced Vessel Analysis gives incorrect measurements if adjust tracking Product Quality Fixes SmartPrep reliability improvements SmartView reliability improvements Start up Shut down reliability improvements Unable to start New Patient (pixMgmt crash) Images fail to Auto View on LightSpeed 4.X 3 IG systems if SmartPrep used Edit Patient fails due to EditPatientData.ct file not updated correctly Alt F4 crashes Display process or Display Manager process Time drift and time jump Multi language Auto voice defaults to reconfig default voice at End Exam Images fail to transfer to a Kodak PACS Images fail to copy or restore from CD/DVD Unable to Save Multi Step protocols in Reformat or Volume Viewer Enhancements / Improvements Auto Transfer by Series for Scouts Auto Transfer for Dose Report Warning message posted that Auto mA is turned “off” when patient orientation and patient entry do not match the scout series Prospective Multi Recon for Cardiac scan type User selectable series description for Retro recon, Reformat and Volume Viewer mA limited if Tube Warm Up skipped on LightSpeed Pro16 systems IQ Snap -- reserve the scan data files related to images with IQ issues for further investigation Full and Partial Anonynous patient levels Scan date added to Large Image Font Screen Save of Exam or Series text page Patient Name and Patient ID added to update parameters in Connect Pro Save Restore System State time optimized
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required