Tube rotor does not come up with rotation inverter overcurrent. Tube rotor does not come up with rotation inverter overcurrent

Error message

Error: 260118170 (40-0107) Rotation Inverter permanent overcurrent See LD for error explanation Code 40 Error code: 40-0107H Message/explanation: Rotation Inverter permanent over current An over current has been detected and 3 restart have been tried unsuccessfully within a single rotation state Potential cause: Tube stator winding problem (shorted) Incorrect wiring (shorted) Rotation board Recommended action/ Troubleshooting guide: Check stator windings impedance. If not OK, replace tube. Check wiring from rotation board to tube. Check that phase shift capacitors are correctly connected and not in short circuit. Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5271812 replaces 2349603 Power Brush Tip Kit See the Long Description for details refer to service note SN09092411a that is attached to long description Part #: 5271812 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Power Brush Tip Kit FRU: Yes Status: Orderable Comments: Kit contains 5 power brush tips and caps. Order a quantity of 4 for an entire set of power brush tips. 212007413, Aug-2009 Per ECR 2087298, 212008898, 7/20/09.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.