Fanbeam Calibration Processing Failed on Radial
Symptom
Fanbeam Calibration Processing Failed on Radial Case Results: Fanbeam Calibration Processing Camera Name: Infinia Hawkeye Fifina IP Address: 192.168.251.192 Date: 06/05/2009 12:51:23 Name: Service user Input parameters Name Value Accumulated counts of serie 1 3367233 Radial position detector 2 serie 2 140.0 Starting angle detector 1 serie 1 0.0 Table height serie 2 805.6 Study name Infinia Hawkeye Fifina_FanBeam Radial position detector 1 serie 2 140.0 Starting angle detector 1 serie 2 0.0 Table height serie 1 785.6 Accumulated counts of serie 2 2916260 Radial position detector 1 serie 1 160.0 Radial position detector 2 serie 1 160.0 Isotope Tc99m Detectors Results Detector 1 Name Value Status Rule Fanbeam xCor A -4.36 mm Passed >=-5.0 and <=5.0 Fanbeam effective focal distance 401.02 mm Passed >=350.0 and <=450.0 Fanbeam focal projection -6.42 mm Passed >=-15.0 and <=15.0 Fanbeam xCor B 0.01 mm Passed >=-5.0 and <=5.0 Fanbeam effective radial 1 222.52 mm Failed >=200.0 and <=220.0 Detector 2 Name Value Status Rule Fanbeam xCor A 3.08 mm Passed >=-5.0 and <=5.0 Fanbeam effective focal distance 395.73 mm Passed >=350.0 and <=450.0 Fanbeam focal projection -4.41 mm Passed >=-15.0 and <=15.0 Fanbeam xCor B -0.03 mm Passed >=-5.0 and <=5.0 Fanbeam effective radial 1 214.82 mm Passed >=200.0 and <=220.0 Logs [12:51:23 PM] Init Started [12:51:23 PM] Init Ended [12:51:31 PM] Start was pressed Contributor 100008553 B.Certo September 16, 2009
Applies to
- Models
- Infinia
- Product
- Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software) Infinia II Infinia II Acquisition System
- Software
- Infinia All Infinia All. Including Infina 1 and Infinia II. Infinia All. Including Infina 1 and Infinia II.
- Component
- *Collimator/ Collimator cart Collimator/ Collimator cart
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.