GE Healthcare · CTLightSpeed1841881708517135171401723017095
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
Missed ISD See Long Description Inter Scan Delay ISD Missed .
Error message
Error: 184188 Timing (in mS) since end of last scan Col:17085 DvRdy:17135 GenX:17135 TrigEn:17140 ExpEn:17230 See Long Description for more details Wed Nov 8 11:01:40 2006 Error: 184188 Host: STC Process: Scan Control File: scTrigSeqActions.c 1.65 Line: 1048 Function: No System Function Reported Scan: 496/2/2 Type: Axial Exception Level: Pri/Soft Time: 11:01:40:295 Log Series: 938 Last Hdw Rdys- Offsets:0x40 Cpb:0x20 Xray:0x80 Timing (in mS) since end of last scan. RxRcvd:-670 DoRdy:95 OfSt:165 Cpb:17085 OfStp:17095 Cr:810 Ax:100 GenP:175 Das:160 Col:17085 DvRdy:17135 GenX:17135 TrigEn:17140 ExpEn:17230 (Rdy:0xf00e2fff Of:0x540 Auto:0x57c Cpb:0x4057c Xray:0x80bff) This Error code is can give you a clue as to where the problem is coming from, the vaules are in milli-seconds. See Decoding examples below, the Example are only a few of the possiblities. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Example 1: This example shows the Col: ( Co llimator ) is taking over 17 seconds, and since the Collimator should only take less than a second the problem could be the in the collimator. The requested ISD was 3 sec. Timing (in mS) since end of last scan. RxRcvd:-670 DoR
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5140001-3 (replaces 5140001-2) Helios 3 collimator with notched filler bar and rating plate (used on 1.X-4.X) See Long Description for more info Part #: 5140001-3 Part Type: GP REPAIRABLES Part Weight: 115.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: helios 3 collimator with notched filler bar and rating plate FRU: Yes Status: Orderable Comments: ** FE Assist ** 1.x 2.x 3.x 4.x started with Ultras added minor quality improvements to the dash 2 and is backwards compatible (12/6/06 212001261) Part #: 5140001-2 Part Type: GP REPAIRABLES Part Weight: 0.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: helios 2 collimator with notched filler bar and rating plate FRU: Yes Status: Orderable Comments: This part is replacement for 2214768-2, please do not use stock of 2214768-2. ms13452 050516 Can use the 5140001-3 if no Stock of the -2 (9/26/05 212001261)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.