GE Healthcare · CTLightSpeedVCT26013279650089230023052
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner allows tube warm-up but not Fastcals. Scanner allows tube warm-up but not Fastcals
Error message
Error: 260132796 The Following Digital Interface Boards Are Missing/Faulty. See Long Description for complete error Mon Feb 6 09:42:29 2006 Error: 260132796 Host: orp Process: orp_subsys File: IfbConfig.cxx Line: 96 Mon Feb 6 09:42:28 2006 Host : Das Ermes # : 260132796 Exception Class : Abort Severity : Secondary File : IfbConfig.cxx Line# : 96 Function : No System Function Reported Scan Type : Static Scan: 50089/1/1 The Following Digital Interface Boards Are Missing/Faulty. Digital Interface Boards: 19 Error: 230023052 Failed in Interprocess Communication with Firmware. See long description for details Fri Apr 4 07:32:59 2008 Error: 230023052 Host: chhvct Process: dailyPrepRx File: DailyPrepShellMgr.c Line: 2618 Failed in Interprocess Communication with Firmware. Critical software failure. Cannot continue.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required