GE Healthcare · CTLightSpeedVCT260125005260112011244633
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Gantry shutdown itself for 1 minute and then reset on its own. GANTRY SHUTDOWN ITSELF FOR 1 MINUTE AND THEN RESET ON ITS OWN BETWEEN SCOUTS AND AXIAL SCANS.
Error message
Error: 260125005 Table Communication - Watchdog timeout. See long description for complete error Wed Jan 17 08:33:42 2007 Error: 260125005 Host: tgp Process: tgp subsys File: ta callback gt.c Line: 296 Wed Jan 17 08:33:42 2007 Host : Table Gantry Processor Ermes _ : 260125005 Exception Class : Secondary Severity : Pri/Soft File : ta callback gt.c Line_ : 296 Function : SYSTEM COMMUNICATIONS : Table Communications Scan Type : None/Unknown Scan: 6492/1/0 Table Communication - Watchdog timeout. Probable software problem. Error: 260112011 Received Table Rx but the Table was NOT READY Error : 260112011 Received Table Rx but the Table was NOT READY Thu Sep 1 08:49:43 2005 Error: 260112011 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr.c Line: 3197 Thu Sep 1 08:49:44 2005 Host : Table Gantry Processor Ermes # : 260112011 Exception Class : Soft Severity : Pri/Soft File : uif_table_tilt_mgr.c Line# : 3197 Function : No System Function Reported Scan Type : Helical Scan: 8439/4/1 Received Table Rx but the Table was NOT READY for Scanning. Error: 244633 Table reports that Table Communication becomes down. Wed May 25 17:35:00 2005 Error: 244633 Host: ct01 Process: fwmgr File: fwmgr_ev
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required