Symptom
Scan Aborts with JEDI XG Error. Scout Scan Aborts with JEDI XG Error
Error message
ER-123 XG Error See long description for detailed error codes ER-123 XG Error detailed code 535 - Anode over mA ER- 123 XG Error ERROR CODE=xyz, %%%KV, %%%MA, HV TIME=%%%%msec XG Error OC software detected error status from XG. x: 0:Test Mode. 1:Standby. 2:Initializing. 3:Generator Ready. 5:Exposure. 7:Transition Step to Standby. yz: 01:DC_BUS_BAL_ERROR. 03:DC_BUS_UNLOAD_ERROR. 04:DC_BUS_UNDER1_ERROR. 05:DC_BUS_OVER1_ERROR. 06:DC_BUS_UNDER2_ERROR. 07:DC_BUS_OVER2_ERROR. 08:DC_BUS_UNDER_ERROR. 09:DC_BUS_OVER_ERROR. 16:Stator current error. 18:Stator current unbalance error. 19:Rotor status error. 21:Over filament current error. 22:Filament open error. Filament current feedback is out of range. 24:Filament supply error. 25:When the digital error signals coming from the inverter are active and when the filament is ON and it should not be. 31:Tube current accuracy error. 32:Tube voltage accuracy error. 33:Spit error. 34:Backup time error. 35:Anode over mA error. 36:Cathode over mA error. 37:Anode over kV error. 38:Cathode over kV error. 39:Shotthru error. 41:Overcurrent error. 43:HV_ON error. 44:Unbalance negative kV error. 45:Unbalance positive kV error. 48:Generator safety loop. 49:S
Applies to
- Product
- Sytec 1600i/1800i SYj Eu Sytec 1600i/1800i SYj Eu Sytec 1600i/1800i SYj Eu Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3512T X ray tube used on Sytec 1800i / 1600i See lond description Part #: D3512T Part Type: GP TUBES Part Weight: 0.91 KGM Repairable: No Returnable: Yes Hazardous Material: N Description: CT PLUS TUBE UNIT RELOAD FRU: Yes Status: Orderable Parts Offered as: Current: D3512T Harvested: Not Available Exchange: Not Available Comments: FLS - MAXIRAY EQUIVALENT IS D3519T *WARNING: CT PLUS IS A NEW TUBE DEDICATED FOR SYTEC 1800I, SYTEC 1600I AND CT EMYU SYSTEMS ONLY. PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI 28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS *NOT* COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FLS - CT PLUS TUBE. FOR SYTEC 1800I, SYTEC 1600I AND CT EMYUSYSTEMS ONLY. "WARNING: PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS NOT COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FOR THESE SYSTEMS YOU SHOULD PLACE ORDER FOR CT MAX TUBE: D3502T. PLEASE CALL ONLINE CTR IF YOU NEED FURTHERCLARIFICATION." CPD TEAM: NO SYSTEMS IN USA IN 1998. IF FOR DOMESTIC ORDER, FE IS PROBABLY ORDERING INCORRECTLY. (D HAWVER 9/24/98) SOURCE = ASIA (GE-BEL IN INDIA) TUBE DEDICATED FOR SYTEC 1800I, SYTEC 1600I AND CT EMYU SYSTEMS ONLY. PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI 28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS *NOT* COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FOR THESE SYSTEMS YOU SHOULD PLACE ORDER FOR CTMAX TUBE: D3502T* PLACE ORDER FOR CTMAX TUBE: D3502T*
- Area
- CT