Symptom
"Scan hardware Stopped Scan" with scan data errors. "Scan hardware Stopped Scan" with scan data errors
Error message
Error: 230011073 STUB -SCANFILE_HEADER_callback See LD for full error Mon Jun 27 09:56:31 2005 Error: 230011073 Host: ct01 Process: headermgr File: sdio_xfs_api.c Line: 4074 STUB - SCANFILE_HEADER_callback Fri Sep 29 13:35:26 2006 Error: 230011073 Host: ct01 Process: badchanmgr File: sdio_xfs_api.c Line: 4101 STUB - SCANFILE_HEADER_callback Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 2 --- No such file or directory then repeats ... Fri Sep 29 13:35:26 2006 Error: 230011073 Host: ct01 Process: scanmgr File: sdio_xfs_api.c Line: 4101 Function: Data Acquisition : SBC Processing Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 11 --- Resource temporarily unavailable then repeats... Fri Sep 29 13:35:46 2006 Error: 230011073 Host: ct01 Process: scanfile_xfer File: sdio_xfs_api.c Line: 4101 Function: Image Generation : SBC Processing Scan Type: Not scanning Scan: 41/3/1 Error detected closing information file. Shutdown processing will continue. Info file: /raw_data/info_file OS error : 13 --- Permi
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required