LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2
Symptom
Unable to scan with a message on screen that says: Collimator/DAS reset failed.
Error message
Error: 244586 the following hardware subsystems reported a failure when initializing: OBC SS (Coll/Das) See the Long Description for the complete error code Error: 244586 Host: qx-ct Process: fwmgr File: HwSetUp.c Line: 2235 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 The following hardware subsystems reported a failure when initializing: OBC SS(Coll/Das) Do Not Use - use one of the other Error: 260001008 The OBC failed to connect with the ? (DCB and/or the CCB) sub-system in the allotted time Open Long Description to see error example Mon Mar 28 03:39:48 2005 Error: 260001008 Host: OBC Process: HOP File: hop_node_init.c Line: 120 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 03:39:46:170 Log Series: 31 The OBC failed to connect with the DCB (could be the CCB) sub-system in the allotted time. Check to see if subsystem is alive. Timeout value: 40000mS Error: 178570 Coll/Das controller reports failure in initializing tasks See Long Description for complete error Mon Mar 28 03:39:48 2005 Error: 178570 Host: ct04 Process: fwmgr File: HwSetUp.c Line: 3178 Function: No system function re
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2 This is HP CPU host running LINUX with Pegasus IG. 308L.8_H3.3M4 ~ 4 or 8 slice MDAS. ~ Could be an Ultra, Plus or QXi system. Must run swokinstall -p to verify. ~ See Long description for details . LightSpeed 3.X MDAS4 Gantry and GOC2 Gantry - 2281177-2, DAS - 2272768, Console – 2341104-2, Table - 2276776, PDU - 2269902 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2253562 EIGHT SLICE DAS CONTROL BOARD also used on MDAS 4 See Long Description Part #: 2253562 Part Type: GP CONSUMABLES Part Weight: -13639.86 KGM Repairable: No Returnable: No Hazardous Material: N Description: EIGHT SLICE DAS CONTROL BOARD FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 2253562 Harvested: Not Available Exchange: Not Available Comments: FLS - EIGHT SLICE DAS CONTROL BOARD.USED ON WARP3. SUPPLIER IS SCI. MSA6724 EJM 05/16/01 COLLECTION OF DEFECTIVES START7/23/01 MS5277 TAKEN OFF RECYCLING PROGRAM PER L.BENIWAL (MSA8429 08/20/02) GELS - LIGHTSPEED ULTRA DCB / OPTIC FIBER FREQ 33 MHZ / NEEDS DIP BOARD REF 2259530 PDB 02/01/21 DNA FOR A REWORK TO PURGE MATERIAL FOR QUALITY ISSUE PER REQUEST O CT ENG/A REGAL 03/01/20,DAS CONTROL BOARD
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.