GE Healthcare · CT182904182908
Lightspeed 1.X - Octane
Symptom
Table foot pedals malfunction. Table foot pedal malfunction.
Error message
Error: 182904 A table side key is either stuck or pressed during initialization See long description for full error Tue Sep 11 09:36:32 2007 Error: 182904 Host: ETC Process: Table Controls File: tc_exec.c 1.27 1/15/96 Line: 475 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 09:36:27:725 Log Series: 27 A table side key is either stuck or pressed during initialization or just after Emergency Off released. Port value 0x0100. Error: 182908 Up Footpedal is non-functional. Use the Tableside buttons See long description Fri Jul 31 08:38:45 2009 Error: 182908 Host: ETC Process: Table Controls File: tc_exec.c 1.27 1/15/96 Line: 382 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Sec/Soft Time: 08:38:37:040 Log Series: 20 Up Footpedal is non-functional. Use the Tableside buttons.
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-296129G1 FOOTSWITCH used on Zeus style tables 1x through 4x plus CTi and HSA See long description for details Part #: 46-296129G1 Part Type: GP CONSUMABLES Part Weight: 3.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: FOOTSWITCH FRU: Yes Status: Orderable FLS - THIS IS A 9-PIN MOLEX CONNECTOR USED WITH THE CT/I HISPEED, QX AND QXI PLUS CT SYSTEMS. THIS MOVED TO GEHW AS PART OF THE GPC CHINA TABLE MOVE
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required