GE Healthcare · CTLightSpeed18261925065
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops. Gantry tilts slowly 1 degree and stops - table moves very slowly 5mm and stops
Error message
Error: 182619 The Gantry BACK ( or FORWARD) Touch Sensor Error(s). Remote Tilt is DISABLED. See LD for complete error Wed Oct 10 11:37:56 2007 Error: 182619 Host: ETC Process: Tilt File: tmcTouchSensor.c Line: 136 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 4417/4/0 Type: None/Unknown Exception Level: Pri/Soft Time: 11:37:57:660 Log Series: 263 The Gantry BACK Touch Sensor Error(s): Console Pushbutton Remote Tilt is DISABLED. Use Gantry Controls to Tilt the Gantry. Cur Pos 15 (.01 deg). Tilt Dir:0 (0:BCK 1:FWD) Tilt Cmd:2 (1:Remote 0:Local) (TouchSensor: 0x8000). Wed May 7 11:45:05 2008 Error: 182619 Host: ETC Process: Tilt File: tmcTouchSensor.c Line: 136 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 25065/2/1 Type: Axial Exception Level: Pri/Soft Time: 11:45:06:015 Log Series: 50 The Gantry FORWARD Touch Sensor Error(s): Console Pushbutton Remote Tilt is DISABLED. Use Gantry Controls to Tilt the Gantry. Cur Pos 19 (.01 deg). Tilt Dir:0 (0:BCK 1:FWD) Tilt Cmd:1 (1:Remote 0:Local) (TouchSensor: 0x4000).
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2277404 Patient Tilt Sensor, Large for Rear Gantry Cover used on HiSpeed QXi, 2.x(Plus), 3.x(Ultra), 4.x(16 Slice), HPower and VCT gantries See Long Description for Part Details 2277404 Patient Tilt Sensor, Large for Gantry REAR Cover Asm. Part #: 2277404 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: PATIENT TILT SENSOR, LARGE FRU: Yes Status: Orderable Comments: FLS - H2 GANTRY. COMMON TO MFG MS26561 DSM 1/7/01 REAR LARGE SWITCH/PART OF 2273016 REAR GANTRY COVER COLLECTION OF DEFECTIVES START7/23/01 MS5277
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required