GE Healthcare · CTLightSpeed26000314113155260003139
LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry
Symptom
"Scan hardware Stopped Scan" with collimator errors. "Scan hardware Stopped Scan" with collimator errors
Error message
Error: 260003141 Filter homing problem. See the Long Description for the full error code Fri Mar 4 21:22:12 2005 Host : Collimator Ermes # : 260003141 Exception Class : Abort Severity : Primary File : filter_home.c Line# : 147 Function : No System Function Reported Scan Type : None/Unknown Scan: 13155/1/0 Filter homing problem. Error: 260003139 Filter Switch Error. Both Contacts Are Either Open or Closed. See Long Description for complete error. Error: 260003139 Host : Collimator Ermes # : 260003139 Exception Class : Soft Severity : Pri/Soft Filter Switch Error. Both Contacts Are Either Open or Closed. They Should be the inverse of each other Filter Switch NO Contact: Open Filter Switch NC Contact: Open
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5140001-4 helios 4 collimator with notched filler bar and rating plate used on 5.X scanners. See Long Description for Details. Part #: 5140001-4 Part Type: GP REPAIRABLES Part Weight: 2.20 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: helios 4 collimator with notched filler bar and rating plate FRU: Yes Status: Orderable Comments: Added by ECR 2013518 as ms13452 050428 **FE Assist** Used on H-power - main difference is the mount holes are larger to accommodate for larger bolts to hold the added weight of the Hercules Tube. 5140001-4 is also used on HP-60 s . 514001-4 is not backwards compatible.(12/5/06 212001261) *** 2ND OPINION NOTES *** Replacing for artifacts? Look into collimator with bright light. Any particulate? Look at plastic over copper filter, any distortion or yellowing? Bow tie filter ok? There are several lower level FRUs. Ensure that one of the lower level FRUs could not fix the problem.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required