GE Healthcare · CTHiSpeed8000002200302314200302183
Intermittent SCSI Operation - Save State Issues - Save State takes too long.
Symptom
Intermittent SCSI Operation - Save State Issues - Save State takes too long.
Error message
Additional sense indicates Write protected - seen in messages See Long Desription for details Jul 17 13:48:11 lqxi kernel: SCSI cdrom error : host 3 channel 0 id 4 lun 0 return code = 8000002 Jul 17 13:48:11 lqxi kernel: Current sd0b:00: sense key Data Protect Jul 17 13:48:11 lqxi kernel: Additional sense indicates Write protected Jul 17 13:48:11 lqxi kernel: I/O error: dev 0b:00, sector 0 The media was write protected Error: 200302314 Failed to save the /usr/g/cal_db file(s). See Long Description for complete error Fri Jul 17 13:49:41 2009 Error: 200302314 Host: lqxi Process: sysStateABB File: ss_gr_saverest.c Line: 206 Failed to save the /usr/g/cal_db file(s). Error: 200302183 System call failed. Error: No such file or directory See Long Desription for complete error Fri Jul 17 13:48:33 2009 Error: 200302183 Host: lqxi Process: sysStateABB File: ss_osdep.c Line: 98 System call failed. Error: No such file or directory Command: ls /DVD/service_mod_data/system_state/scanRx.db > /dev/null 2>&1 Fri Jul 17 13:49:40 2009 Error: 200302183 Host: lqxi Process: sysStateABB File: ss_osdep.c Line: 98 System call failed. Error: No such file or directory Command: tar -Pcf /DVD/service_mod_dat
Applies to
- Models
- HiSpeed
- Product
- HiSpeed QX/i - GOC2 103L.5_HSQXIM4 103L.4_HSQXIM4 102L.1_HSQXIM3 HiSpeed QX/i - GOC2 Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types GOC2 List of softwares the product can run 103L.5_HSQXIM4 103L.4_HSQXIM4 - obsolete 102L.1_HSQXIM3 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required