Pular para o conteúdo principal
GE Healthcare · CT200900025

Lightspeed 1.X - Octane

Symptom

Connect Pro Modality Work List will not update. Connect Pro Modality Work List will not update

Error message

Error: 200900025 Generic Patient Worklist Error , See Long Description for full errors See Long Description for errors The error can be in different contexts per the below Thu Jan 4 10:12:21 2007 Error: 200900025 pct01 WLServer WLapiSystem.c 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLServer.c, Line: 1609, Status: 28 Fatal Unknown DCM ERROR Mon Sep 19 08:28:09 2005 Error: 200900025 ct01 piRxMgmt WLapiSystem.c 190 Function: Data Management : OC Processing Patient Worklist Manager error Source File: WLapiWorklistFile.c, Line: 6038, Status: 3 WLgetTime(): Could not read from /usr/g/db/patientInfo/Update.db. PS000007990.db for reading. Error: 200900025 Host: ls08 Process: WLServer File: WLapiSystem.c Line: 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLS_mfm.c, Line: 1465, Status: 23 Parse Failed : Patient Worklist Manager HIS(40)(3) :-104 Error: 200900025 Process: WLServer File: WLapiSystem.c Line: 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLServer.c, Line: 293, Status: 19 DICOM Association Inactivity Time-out Tue Sep 26 09:51:49 2006 Error: 2

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues