Infinia Hawkeye CT image shows some slices which are distord, some slices only have part of the image, some sl…
Infinia Hawkeye CT image shows some slices which are distord, some slices only have part of the image, some slices are blank and reconstruction is slow.
Symptom
Infinia Hawkeye CT image shows some slices which are distord, some slices only have part of the image, some slices are blank and reconstruction is slow.
Error message
CT_ERROR_SPITS (Error 6695) CT_ERROR_HVPS_ARC_FAULT (Error 6209) CT_AIR_TABLE_PROJ_ERROR (Error 6917) [email protected] CT_AIR_TABLE_PROJ_ERROR (Error 6917) [email protected] 07:21:06 WARNING = Warning in PEFApp in Class Message.java:132 - DEVELOPMENT_ERROR_MESSAGE=Air Table Creation Utility - Failed to obtain the requested projections! USER_ERROR_MESSAGE=Air Table Creation Utility - Failed to obtain the requested projections! USER_FIX=None CODE=(CT_AIR_TABLE_PROJ_ERROR,6917,ERROR) SOURCE=com.ge.med.fi.tacq.hwifc.VG.VGCT@1060ee9 TIME_CREATED=Wed Jan 07 07:21:06 CST 2009 CT_ERROR_MAX_SPITS_REACHED (Error 6620) CT_ERROR_MAX_SPITS_REACHED [email protected] CT_ERROR_MAX_SPITS_REACHED (Error 6620) [email protected] 07:21:05.750 [th:02768] ERROR=Error in CTServer d:\tacq\su\src\cpp\ct\hawkeyems\device\hkmsfileprojections.cpp(322): setStep: add_data returned with status 8 - MAX_SPITS_REACHED_ERROR
Applies to
- Models
- Infinia
- Product
- Infinia II Infinia II Acquisition System Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software)
- Component
- 5272336 Hawkeye 1 slice TTH X-Ray Generator 5272336 Hawkeye 1 slice TTH X-Ray Generator
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.