GE Healthcare · CTLightSpeedVCT
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Phantom Holder is bent, broken, cracked, or damaged See long description and must be replaced.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2331933 METALLESS PHANTOM HOLDER 2331933 METALLESS PHANTOM HOLDER Part #: 46-222986G2 Part Type: GP CONSUMABLES Part Weight: 5.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: METALLESS PHANTOM HOLDER FRU: Yes Status: Orderable Comments: FLS - DESC: METAL-LESS COMPATIBLE PHANTOM HOLDER. THE 46-222986G2 IS NOT A DIRECT REPLACEMENT FOR THE G1 (G2) IS METAL-LESS. ALSO PINHOLDER ON THE CRADLE MOUNT MUST BE REMOVED FROM THE G1 AND PUT ON THE G2 IN ORDER TO BE ABLE TO USE THE G2 IN PLACEOF THE G1. IF THE PINHOLDER ON THE G1 IS DEFECTIVE, THE GE WILL NOT BE ABLE TO BE INSTALLED. 1/9/97 GWENN 08992 ALSO USED ON HINO CT/E PINHOLDER IS 46-222987G1 P/N 46-222986G2 WILL BE REPLACED BY P/N 2331933 (ASIA SOURCED) PER PCN 220526. USE EXISTING STOCK FIRST. ADDED BY MS20544 ON 6/9/02.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required