GE Healthcare · CTLightSpeedVCT26011816726011823654034
LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118167 (40-0104)Rotation current open load. Rotation board detected that no current is flowing to the motor. Wed May 12 13:54:03 2004 Error: 260118167 Host: orp Process: orp_subsys Wed May 12 13:54:02 2004 Host : Jedi Ermes # : 260118167 (40-0104)Rotation current open load. Rotation board detected that no current is flowing to the motor. Z6,Z7=7h,0h Code 40 Error code: 40-0104H Message/explanation: Rotation current open load Rotation board detected that no current is flowing to the motor. Potential cause: 1. Tube stator winding is open circuit: x-ray tube 2. Incorrect wiring (Open) 3. No DC bus on Rotation board 4. Phase shift capacitors not connected 5. Rotation board Recommended action/ Troubleshooting guide: Disconnect rotation-to-tube-stator cable and check stator windings impedance ohm). If open circuit, replace tube. Check wiring from rotation board to tube. Check DC bus voltage present on rotation board. Troubleshoot cables and fuses from Pi Filter board to rotation board Check that phase shift capacitors are correctly connected Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board Error: 260118236 - (70-0501) DC bus out of range
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2336517-2 Fuse 25 A 700 V 2.5M seconds - used in Jedi Generator See Long Discription for Details Part #: 2336517-2 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: FUSE 25 AMPS 700 VOLTS 2.5M SECONDS FRU: Yes Status: Orderable Comments: This part is used in Fuse Kit's for Hpower (2218570-2), Hp60 (2385412)and VCT 5125429). Please check order as Fuse Kits, ms13452
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required