BrightSpeed Select or Delight Select
Symptom
OLC or RSE or RST remote Engineer needs to run "quicksnap" remotely. CAUTION: quicksnap should not be run during data collection. Running ""quicksnap" during data collection could cause the recon engine to fail and interrupt data collection, just wait until the exam is over before running quicksnap. The Easy way to run quicksnap is only two steps - 1 open a unix shell 2- type quicksnap then just following - instructions on the screen. OLC or RSE or RST remote Engineer needs to run "quicksnap" remotely. CAUTION: quicksnap should not be run during data collection. Running ""quicksnap" during data collection could cause the recon engine to fail and interrupt data collection, just wait until the exam is over before running quicksnap. The Easy way to run quicksnap is only two steps - 1- open a unix shell 2- type quicksnap then just following - instructions on the screen. quicksnap INFO: runtime Minimum 15 sec Maximum 120 sec, Ave 30 seconds. The customer could run quick snap from Image Works -> select Browser then the tool chest will be in the upper right had corner of the screen. In the tool chest a button for quicksnap is available. The quicksnap tool is used by engineering to collect needed timer files and various other logs from the system. The quicksnap tool can be used for data gathering when you are gather information for a PQR/PSR.
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed Select, Delight Select or MERI Select Elite-16, Edge-8, Excel-4 HP_S_G16_G_HLT HP_S_G8_G_HLT HP_S_G4_G_HLT BrightSpeed Select or Delight Select (Hivalue Lite) 4/8/16 Slice Scanner BrightSpeed Delight Select Systems started to ship in first Quarter or 2009 with AIO (All in One) Console. AIO console uses HP8400 and NO DARC or IG's. Recon time is 6 FPS. If customer orders Fluoro option system requires one IG. The 16 FPS Upgrade in Not Available for Select systems. BrightSpeed Meri Select Systems ( Pancake Das ) started to ship in 3rd quarter of 2010, 4/8/16 Slice Scanner HiValue 16 Lite −−> BrightSpeed Elite Select HiValue 8 Lite−−> BrightSpeed Edge Select HiValue 4 Lite−−> BrightSpeed Excel Select BrightSpeed Select Scope: - 3.5MHu Solarix tube - JEDI 60 dc Lite - Modified NP Table Key Features: - 16x0.625mm(16x1.25) for Lite 16 - 8x1.25/8x2.5mm for Lite 4/8 - Rotation Speed: 0.8 s - Gantry: 2040mm width, 70cm Bore - Table: 1337@ISO-140mm scannable range - Recon: 3fps (w/o IG @ 2G Memory(4/8), 4G Memory(16)), optional: 6fps(w/ 1IG ) - Power: 42KW JEDI power See the attached Service Intro Planner for details Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required