GE Healthcare · CTHiSpeed260118169
CT/e Dual, CT ProSpeed AII/FII Irix or Linux
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118169 (40-0106 ) Rotation phase error See Long Description for error explanation Error: 260118169 (40-0106 ) Rotation phase error Error code: 40-0106H Message/explanation: Rotation phase error The Rotation board has detected that the current in the anode stator does not show the correct phase shift between main and auxiliary. Potential cause: 1. Tube stator winding problem 2. Incorrect wiring (one wire open) 3. Phase shift capacitors inverted or wrong value or not connected 4. Rotation board Recommended action/ Troubleshooting guide: Disconnect rotation-to-tube-stator cable and check stator windings impedance. If not OK, replace tube. Check wiring from rotation board to tube. Check that phase shift capacitors are not swapped, check connection Check that phase shift capacitors are not in short-circuit Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board
Applies to
- Models
- HiSpeed
- Product
- CT/e Dual, CT ProSpeed AII/FII Irix or Linux HiSpeed CT/e Dual CT Scanner System see long Description for sales information Product Name: CT/e Dual CT Scanner System Irix A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) N/A Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2215674 rotor capacitor set used on ProSpeed FII See LD for details 2215674 rotor capacitor set used on ProSpeed FII Part #: 2215674 Part Type: GP CONSUMABLES Part Weight: 2.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: ROTOR CAPACITOR SET 23/23 FRU: Yes Status: Orderable Parts Offered as: Current: 2215674 Harvested: Not Available Exchange: Not Available Comments: GELS - DEFECTIVE PARTS TO BE PUT ON SHELVES FOR ANALYSIS FP99/04,ROTOR CAPACITOR 23/23 FLS - ROTOR CAPACITOR 23/23 U/O YMS PROSPEED LXI,FXI,DXI REPLACES 2187003 JEDI GENERATOR
- Area
- CT