Symptom
Not able to pull up patient schedule when pressing new patient button.
Error message
Error: 200501537 Previous message error was of type Button Request with sequence number 56 see long description for error details Thu May 7 20:34:39 2009 Error: 200501537 Host: ctls Process: examRxEnv File: uifIpcCommonFunctions.c Line: 1468 Function: No system function reported Previous message error was of type Button Request with sequence number 56 and button code 1013 Error: 200501530 Send of message with event code xxxxx from service yyyyy to zzzzzz failed with status: see long description for error details Thu May 7 20:34:39 2009 Error: 200501530 Host: ctls Process: examRxEnv File: uifIpcCommonFunctions.c Line: 1723 Function: No system function reported Send of message with event code 6000 from service uif_exam_rx_env to uif_patient_mgmt failed with status: IPC failure. Error: 200510036 --- error 200001822 from uifIpcSendButtonReq for button 1012 See long desscription for error details Thu May 7 20:34:37 2009 Error: 200510036 Host: ctls Process: examRxEnv File: ExamPrescriptionTPMgr.c Line: 1512 error 200001822 from uifIpcSendButtonReq for button 1012 Error: 200001830 IPC failure caused by cupIpcConnect from uif_exam_rx_env to uif_patient_mgmt Thu May 7 20:34:39 2009 Error
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required