Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT

LightSpeed 1.X - GRE

Symptom

"Scan hardware Stopped Scan" with DAS power errors. "Scan hardware Stopped Scan" with DAS power errors

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2218157 SDAS 5VD DIGITAL POWER SUPPLY WITH BRACKET - used on H1 gantry See LD for more 2218157 DAS 5VD DIGITAL POWER SUPPLY WITH BRACKET Part #: 2218157 Part Type: GP CONSUMABLES Part Weight: 3.64 LBR Repairable: No Returnable: No Hazardous Material: N Description: DAS 5VD DIGITAL PWR SUPPLY W/BRACKET FRU: Yes Status: Orderable Comments: FLS - DAS 5VD DIGITAL PWR SUPPLY W/BRACKET U/O LIGHTSPEED 3-23-99 MS08992 GWENN HQT: SHORT TERM SITUATION UNTIL 2218157 AVAILABLE FROM MFGING CAN USE 46-251198P3 THIS IS THE POWER SUPPLY WITHOUT THE BRACKET. 3/23/99 MS08992 PCN: 2218157 GELS - "DAS 5VD DIGITAL PWR SUPPLY W/B RACKET U/O LIGHTSPEED IN THE EVENT THAT IT IS NOT AVAILABLE, 46-251198P3 CAN BE USED (THIS IS WITHOUT THE BRACKET) SO THE FE WILL NEED TO HANG ON TO HIS OLD BR",POWER SUPPLY 5V
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues