Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT260125041900824897741749120

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260125041 Motion without command in Elevation drive See LD for more details Wed Jun 14 12:48:32 2006 Error: 260125041 Host: tgp Process: tgp_subsys File: ta_callback_gt.c Line: 508 Wed Jun 14 12:48:31 2006 Host : Table Gantry Processor Ermes # : 260125041 Exception Class : Abort Severity : Primary File : ta_callback_gt.c Line# : 508 Function : No System Function Reported Scan Type : Helical Scan: 412/4/1 Motion without command in Elevation drive Current pos = 900824 Last stop pos = 897741 Tolerance = 3000 Time since last stop = 749120 Last target pos = 1 Hardware status = 0

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5127285 SHUT OFF VALVE ASSY used on GT1700 and GT2000 table See Long Description 5127285 SHUT OFF VALVE ASSY used on GT1700 and GT2000 table Part #: 5127285 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: SHUT OFF VALVE ASSY Positoning GT FRU: Yes Status: Orderable Comments: Not Available
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues