GE Healthcare · CTHiSpeed1832581147818318396082210922183110

HiSpeed CTi 6.X with Octane and HSA Gantry

Symptom

Scanner Hardware Fault with high voltage spits. Scanner Hardware Fault with high voltage spits

Error message

Error: 183258 KV board MAXIMUM spit rate exceeded Fri Jul 9 14:48:13 2004 Error: 183258 Suite: CT01 Host: OBC Process: Generator File: gen abort.c 1.33 Method: No Method Line: 266 Function: XRAY GENERATION : KV Loop Scan: 11478/3/9 Type: Axial Exception Level: Pri/Most Severe Time: 14:48:13:125 Log Series: 945 KV board MAXIMUM spit rate exceeded. Selected technic: 140 kV, 170 mA

Error: 183183 kV out of 3 % tol See Long Description for error example Error: 183183 Suite: CT01 Host: OBC Proc: Generator File: gen tech.c 1.32 Method: No Method Line: 791 Function: XRAY GENERATION : KV Loop 960822 1230 10922 Scan: 0/0/3 Type: Static Exception Level: Sec/Soft Time: 12:17:46:610 Log Series: 529 kV out of 3 % tol Selected technic: 100 kV, 50 mA Tot. samples = 3 Tot. kV samples above tol. = 0, below tol. = 1 Avg. of kV samples above tol. = 0.000 kV, below tol. = 53.871 kV 960822 1230 10922 Avg. of tot. kV = 84.396 kV

Error: 183110 KV fault detected: Cathode overcurrent See Long Description for complete error Wed Sep 28 08:31:12 2005 Error: 183110 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 266 Function: XRAY GENERATION : KV Loop Scan: 13379/2/2 Type: Helical Exception Level: P

Applies to

Models
HiSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2205390 CATHODE HV Tank used on 1.X, 2.x, 3.x, 4.x and HiSpeed LightSpeed Systems - Replaces 2161306 See Long Description for FEMC information and picture 2205390 CATHODE HV Tank used on 1.X, 2.x, 3.x, 4.x and HiSpeed LightSpeed Systems - Replaces 2161306 Part #: 2205390 Part Type: GP REPAIRABLES Part Weight: 30.06 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: BLOC HT CT FAST - POUR EPO FRU: Yes Comments: FLS - HV TANK CT FAST (-) CATHODE REPLACES 2161306 HDQ: 5 IN TRANSIT FROM GEMSE 4/3/98. REPLACES 2161306. PER G.ORME, ONLY DIFFERENCE IS PACKAGING, SO T3# REMAINS THE SAME. C.BRICKLER 4/6/98 ****NOTES FOR CD TEAM************************* ALL PARTS ON HAND HAVE BEEN REPAIRED USING THE NEW PROCEDURES. DO NOT USE THE 2205390H2 PART NUMBER ANYMORE.MS26561 DSM 11/16/01 ** FE ASSIST ** The HV adapter/Spacer part number 2171866 Kit that is included with the HV tanks But it is only used on older Highspeed Gantry due to the smaller bolt size. Refer to MI&CT ESERVICE NOTE SN07091114a for additional details. (212001261 21-Jan-2009) *** 2ND OPINION NOTES *** Check Oil in wells. Prior to ordering tube INSTALL NEW TUBE should be run to regenerate calseed values and set up the gencal table. The tube should be isolated and the KV loop test run to verify with 90% degree of certainty the tube is or is not at fault 4/7/98 2205390 1.0 0.5 SEC/REV CATHODE HV SUPPLY
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.