GE Healthcare · CTHiSpeed

CT/e, CT Prospeed AI/FI Irix or Linux

Symptom

Scanner stopped scan with a popping noise from the YMS HiSpeed gantry See Long Description Scanner hardware stopped scan during patient exam with a popping noise from the gantry and TGP Errors 60 - 0504H, 60 - 0314H & 20-1001-43 found in the log Error code: 60-0504H Message/explanation: Inverter Gate Power Supply error gate supply voltage has dropped below the level required to drive the IGBTs properly Potential cause: 1. Inverter (gate command board) 2. kV control board 3. Generator input voltage too low or line impedance too high Recommended action/Troubleshooting guide: Run HV power diagnostics Error code: 60-0314H Message/explanation: ILR Current time out. The current resonant frequency is lower than expected Potential cause: 1. kV control 2. Inverter 3. Current measurement circuit. Recommended action/Troubleshooting guide: Run HV power diagnostics. ERROR DETECTED BY OGP BOARD Scout Scan Error: 43 Code: 20-1001-43 Name: X-ray On Response Time Out. Class: Error Description: HV ON was not activated by JEDI on Scout Scan after EXPCMD was activated by OGP. Potential Cause / FRU: High possibility on JEDI in case with XG error.; In case without XG Error, JEDI (kV control or CT-IF) and interface between JEDI and OGP

Applies to

Models
HiSpeed
Product
CT/e, CT Prospeed AI/FI Irix or Linux See long description for sale information Product Name: CT/e Single CT Scanner: Irix Platform A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) 3.01 / 3.02 / 3.03 Linux CTe Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found in the attachment Always use the most appropriate documentation for your system.
Component
D3161T / D3162T Venus tube used on CTE (D3161T is NEW non reload version) See Long Description for details X-ray tube D3162T / D3161T , Modified Venus tube Part #: D3162T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX135 CT TH.1.1 RELOAD FRU: Yes Status: Orderable Comments: FLS - ECONOMY SLIP RING CT TUBE (ALSO CALLED CTE HIGHSPEED) 23 OHM (STATOR RESISTOR VALUE) 11/24/99 AM SOURCE = MEXICO FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA Part #: D3161T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MX135 CT TH.1.1 GREEN FRU: Yes Status: Orderable Comments: This is GREEN tube, order only if New is required , If not please SEE D3162T, ms13452
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.