Running Filament Calibrations failed at 80KV at 575ma

Symptom

Running Filament Calibrations failed at 80KV at 575ma See Long Description While Running Filament Calibrations a message is reported to the Filament Calibration Tool, stating Filament Calibration was NOT successful. The Calibration will retry three times before reporting the failure. Pay close attention to the Fit Error percentage, generally the lower the number the better the Fit.

Error message

Filament Calibration was Not Successful See Long Description: Filament Calibration was Not Successful message is reported in the Filament Calibration tool window, this message is not reported to any error log. Filament Calibration will attempt to repeat a Spot size at least three times before reporting it as a failure. The Filament Calibration Tool indicates to the user to restart Filament Cals upon a failure.

Applies to

Models
Discovery
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
08MW39.4 for Discovery CT750 HD 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. - Discovery CT750 HD Collector 5323588 Rev 3 includes OS and Application CD's - Operating System Linux 5.3.8 Software CD 5323584 Rev 1 - Application CT750 HD DVD 5323585 Rev 3 ======================================================= - Class C CT750 5233586 Rev 1 - Class M CT750 5323587 Rev 1 An On-site / Remote identification aid . (Example: check_config) Result from check_config or swhwinfo: 08MW39.4.V40_PS_HD64_G_GTM 08MW39.4.V40_PS_HD64_G_GTL
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues