GE Healthcare · CTLightSpeed2601182235007426011822410105

Scanner Hardware Stopped Scan

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260118223 (60-0402)mA scale error See Long Description for complete error Error 260118223 orp orp_subsys gen_exec.c 2213 Host : Jedi Ermes # : 260118223 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2213 Function : No System Function Reported Scan Type : Static Scan: 50074/1/9 (60-0402) mA scale error. mA has been measured to be either too low or too high with respect to mA demand 20 ms after the beginning of the exposure. Z6,Z7= 0h,0h

Error: 260118224 60-0403 mA out of range See Long Description for complete error Thu Jun 9 14:36:46 2005 260118224 orp orp_subsys gen_exec.c 2150 Host : Jedi Exception Class : Soft Severity : Pri/Soft File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Helical Scan: 10105/2/5 (60-0403)mA out of range Measured mA every 50 msec exceeded 5 percent of mA demand.This error is logged, but does not stop the exposure. Z6,Z7= 0h,0h Note: MA Out Of Range (60-0403) error may be bogus depending on mA scanning mode. If this error occurs during a Helical AutomA scan, please ignore. Jedi Error # 260118224 (60-0403) “Measured mA every 50 msec exceeded 5 percent of mA demand” is an informational message int

Applies to

Models
LightSpeed
Product
LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
D3634T (aka 2378211-2 ) Varian PERFORMIX PRO TUBE used on : HP80 AND LS RT4 See Long Description for details Part #: D3634T Part Type: GP TUBES Part Weight: 176.37 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERFORMIX PRO (VARIAN) TUBE UNIT FRU: Yes Status: Orderable Comments: FLS 11/19/04 (Shawn Fox 212001261) PLEASE remember to complete the Tube report for the tube you are replacing and return it with old tube. The blank Tube report comes with the new tube. If you have any questions, please contact Yolanda Scheper 262-548-2864. If you do not return tube report with old tube, warranty credit can be missed or delayed for your Zone
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.