LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner hung while waiting for prep delay See LD for more details Scanner hung while waiting for prep delay with Error: 182119 LAN Watchdog TIMEOUT for the SBC . and scsi : aborting command due to timeout : pid 1 272980, scsi2, channel 1, id 3, lun 0 Write (10) 00 00 00 4e 47 00 00 40 00 seen in /var/log/messages viewlog Wed Jan 4 13:45:16 2006 Error: 182119 Host: STC Process: Master Exc Handler File: exm_lan_wdog.c Line: 619 Function: No System Function Reported Scan: 13089/2/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 13:45:57:320 Log Series: 591 LAN Watchdog TIMEOUT for the SBC. HW/SW Error: Did not receive LAN watchdog message. Wed Jan 4 13:45:16 2006 Error: 184189 Host: STC Process: Scan Control File: scRxMgr.c 1.48 Line: 249 Function: No System Function Reported Scan: 13089/2/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 13:45:58:305 Log Series: 591 CF error 2103 detected on sending a CF message. SW ERROR: Software Problem. Error occured when writing CF message 10021. more /var/log/messages Jan 4 12:55:23 sfct kernel: cdrom: open failed. Jan 4 13:34:00 sfct kernel: qla1280: ISP System Error - mbx1=297fh, mbx2=0h, mbx3=180ch Jan 4 13:45:15 sfct kernel: scsi : aborting command due to timeout : pid 1 272980, scsi2, channel 1, id 3, lun 0 Write (10) 00 00 00 4e 47 00 00 40 00 Jan 4 13:45:15 sfct kernel: scsi(2): ABORT Command=0xf77c5e00, handle=0x1 Jan 4 13:45:15 sfct kernel: qla1280: Status Entry invalid handle Jan 4 13:45:15 sfct last message repeated 6 times Jan 4 13:45:16 sfct kernel: scsi(2): Resetting SCSI BUS (0) Jan 4 13:45:15 sfct kernel: scsi(2): Resetting SCSI BUS (1) Jan 4 13:45:15 sfct agent: post_agent.c 866 error: Unknown error 2112 Jan 4 13:45:15 sfct agent: post_agent.c 871 error: Unknown error 2112 Jan 4 13:45:16 sfct kernel: SCSI host 2 abort (pid 1272980) timed out - resetting Jan 4 13:45:16 sfct kernel: SCSI bus is being reset for host 2 channel 1. Jan 4 13:45:16 sfct kernel: scsi(): Resetting Cmnd=0xf77c5e00, Handle=0xd, flags=0x2 Jan 4 13:45:16 sfct kernel: scsi(2:1:3:0): Queueing device reset command.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required