GE Healthcare · CTBrightSpeed
BrightSpeed 4/8/16 slice HPower Scanner Elite-16, Edge-8, Excel-4
Symptom
All Lights on the Gantry Display Lit After Switch Off the OC Power See Long Description for Details... All Lights on the Gantry Display Lit After Switch Off the OC Power . When console On/Off swith is turned off, all of the lights on the gantry display lite up
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2404320-2 CONSOLE INTERCOM PRESCRIBED-TILT HUB See Long Description for More ... 2404320-2 CONSOLE INTERCOM PRESCRIBED-TILT HUB Part #: 2404320-2 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: CONSOLE INTERCOM PRESCRIBED-TILT HUB FRU: Yes Status: Orderable Comments: Per ECR 2062448, 212008898, 10/8/08. ** FE ASSIST ** CT/PET Discovery System's must use the P/N 2404320. CT System's must have FMI 25407 or FMI22918 for RT16/Xtra performed prior to installing 2404320-2. Verify Software Configuration before ordering/installing this FRU. To do this, open a Unix Shell and verify one of the following base software versions is installed: ctuser@hostname} swhwinfo -v 07MW11.10_SP2-0-26.Hardware info / 07MW18.4_SP2-0-26.Hardware info / 07BW08.4_SP2-0-26.Hardware info / 08BW17.7 Hardware info / 08BW20.x Hardware info (212001261 10/21/08)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required