GE Healthcare · CTDiscovery24521310700060100024504723000006929144
Exposure Interlock aborted scanning
Symptom
Exposure Interlock aborted scanning. Exposure Interlock aborted scanning
Error message
Error: 245213 Scan was Paused/Aborted by Firmware (or the host) This is mostly a generic error See LD for error examples Error 245213 is a generic error caused by scan file manager Wed Apr 27 01:01:26 2005 Error: 245213 Host: ls16er Process: scanmgr File: scanmgr_events.cxx Line: 1617 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 107000 Scan was Paused/Aborted by Firmware You may also see another form of this error. Thu May 12 17:43:37 2005 Error: 245213 Host: rrmcct16 Process: scanmgr File: scanmgr_lib.cxx Line: 968 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 601000 Scan setup failed on Step:3 (Allocate Scan File). Status:245047 Another form of this error. Fri Jan 12 10:17:15 2007 Error: 245213 Host: ct10 Process: scanmgr File: scanmgr_events.cxx Line: 2318 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 4000 Scan was Paused/Aborted by Host Do Not Use - use one of the other Error: 230000069 Two, or more, unexpected events were detected during scan data transfer. The 230000069 Error has several varation see below. Sun Sep 5 11:10:31 2004 Error: 230000069 Host: darc Process: d
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required