Pular para o conteúdo principal
GE Healthcare · CTDiscovery260118416

LightSpeed/Discovery CT750 HD

Symptom

Quality of High Resolution Images Poor / lacking

Error message

Error: 260118416 A Receive Packet Timeout error was detected in the focal spot position feedback from JEDI. See long description for full error Thu Feb 12 13:24:21 2009 Error: 260118416 Host: orp Process: orp_subsys File: genJediSC.cxx Line: 1900 Thu Feb 12 13:24:19 2009 Host : On-Board Rotating Processor Ermes # : 260118416 Exception Class : Secondary Severity : Pri/Soft File : genJediSC.cxx Line# : 1900 Function : No System Function Reported Scan Type : Axial Scan: 52/2/1 A Receive Packet Timeout error was detected in the focal spot position feedback from JEDI. The total Receive Packet Timeout errors in current scan is 2518. Check the high speed link cable between Tank and ORP.

Applies to

Models
Discovery
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5305181-2 KVMA Measure Cable See Long Description Part #: 5305181-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: KVMA Measure Cable FRU: Yes Status: Orderable Comments: Per HDVCT M4 RSPL, 212008898, 12/18/08.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues