GE Healthcare · CTHiSpeed
HSA RP 2.X HiSpeed Advantage
Symptom
Smoke is seen coming out of the gantry - Itrack must be written Smoke is seen coming out of the gantry Itrack must be written
Applies to
- Models
- HiSpeed
- Product
- HSA RP 2.X HiSpeed Advantage HiSpeed Advantage RP 2.X HiSpeed Advantage RP 2.X FMI 25247 HSA/RP 2.5 Y2K Upgrade Special Tools Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2104227 SBX-ETHERNET daughter board - Used on CTi ETC and STC Assy. See long description for details and picture 2104227 SBX-ETHERNET daughter board mounted on the ETC board in the table. Part #: 2104227 Part Type: GP REPAIRABLES Part Weight: 0.91 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: SBX-ETHERNET FRU: Yes Status: Orderable Comments: FLS - FE & HQ: YOU CAN SHIP T3202BE.THIS OLDER REV BD WILL WORK INALL SYSTEMS. THE NEW REV T3202FY WILL ONLY WORK IN NEW SITES WHICH ORIGINALLY HAD T3202FY **UNTIL** AFTER ZD MANDATORY FMI SHIPS LATE IN 1995. MB 6/95 4/18/01- T3202FY PLANNED FOR DELIST. SOURCING WAITING QUOTES FOR PRICING/LEADTIME. NO POOL ADDS. MS12464 REPLACED BY:T3202FY GELS - FOR SOFT 1.3 OR + ONLY; 46-264832P1 CAN NEVER REPLACE 2104227 2104227 CAN REPLACE P1 IF 1.3 INSTALLED. SP/MB,PCB SCA-LAN 46-264806G1 STC AXIAL CONTROL BOARD See LD for details Part #: 46-264806G1 Part Type: GP REPAIRABLES Part Weight: 1.81 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: AXIAL CONTROL BOARD FRU: Yes Status: Orderable Comments: FLS - FE: READ SN T-1345. IF U455 ONAX BOARD IS BEING SHORTED, THECABLE MAY BE PINCHED. MS8365 4/95 HQ INV ONLY: PCN'S 161734 AND 161831 IMPLEMENTED. STOCK WASPURGED. 8/93 MBELL FLS - FE ASSIST: MS6588 MAY 2002 46-264806G1 = AXIAL BD FOR CT1.0 SEC. AXIAL ROTATION. THIS BOARD HAS THE PALS FOR 1.0 SECOND ROTATION. THE T3202BD =1.0 SEC AXIAL BD. THE T3202KD = .8 SEC AXIAL BD. THE ONLY DIFFERENCE BETWEEN THE T3202KD AND T3202BD ARE TWO PALS. THE T3202BD CAN BE UPGRADED TO THE T3202KD BY CHANGING PALS U211 AND U101. DO YOU STILL WANT TO ORDER THIS PART?? 46-264806G1 STC AXIAL CONTROL BOARD
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required